7. If the unit is equipped with software version 1.13 or less, continue with step 7. If the software
version is 1.14 or greater, skip to step 10.
8. Operate the CROSSRAMP
▲ or CROSSRAMP ▼ keys as required to set the lift calibration
number to 200.
9. Rotate the ramp end cap on the lift motor drive screw until the distance from the upper
surface of the plastic nut in the ramp end cap to the end of the lift motor drive screw is
1-1/2”. If the lift motor drive screw rotates the lift calibration number will no longer be 200.
The lift calibration number must be 200 and the distance measurement must be correct for
the lift calibration to be correct.
10. Set the on/off switch in the “off” position. Do not exit the diagnostic program in the normal
manner. Exiting the diagnostic program will cause the lift to self center and invalidate the lift
calibration just performed. Skip to step 13.
11. Operate the CROSSRAMP
▲ or CROSSRAMP ▼ keys as required to set the lift calibration
number to 139.
12. Rotate the ramp end cap on the lift motor drive screw until the distance from the upper
surface of the plastic nut in the ramp end cap to the end of the drive screw is 10”. If the lift
motor drive screw rotates the lift calibration number will no longer be 139. The lift calibration
number must be 139 and the distance measurement must be correct for the lift calibration to
be correct. See Diagram 5.2.
13. Set the on/off switch in the “off” position. Do not exit the diagnostic program in the normal
manner. Exiting the diagnostic program will cause the lift to self center and invalidate the lift
calibration just performed.
14. Raise the ramp assembly to a convenient height and slide the ramp end cap into the ramp
assembly. Hand tighten the four ramp end cap mounting screws and then torque them to
100 in/lbs.
15. Set the on/off switch in the “on” position. Thoroughly test all lift related functions per Section
Four.
16. Set the on/off switch in the “off” position, replace the front cover per Procedure 7.1.
Diagram 5.2 - Lift Motor Calibration (Version 1,14 or greater)