29. If the unit operated correctly when the new interconnect cable was installed, the original
interconnect cable is bad. Install a new interconnect cable per Procedure 7.7. If the unit
does not operate properly, continue with the next step.
30. Reconnect the original upper interconnect cable to the upper PCA.
Version 2,3
31. Set the on/off switch in the “off” position.
32. Attach the anti-static wrist strap to your arm, then connect the ground lead of the wrist strap
to the units frame.
33. Remove the interconnect cable cover. (See Diagram 7.2)
34. Remove the rear cover. For convenience the upper interconnect cable is the cable that
attaches to the upper PCA and the lower interconnect cable is the cable that connects to the
lower PCA.
35. Connect a known good upper interconnect cable from the lower interconnect cable to the
upper PCA. Route the cable outside of the unit at this time.
36. Check operation as described in Section Four.
37. If the unit operated correctly when the new interconnect cable was installed, the original
interconnect cable is bad. Install a new interconnect cable per Procedure 7.5. If the unit
does not operate properly, continue with the next step.
38. Reconnect the original upper interconnect cable to the upper PCA.
Troubleshooting the Lower Interconnect Cable
39. Remove the shield from the lower PCA.
40. Remove the interconnect cable from the lower PCA.
41. Connect a known good lower interconnect cable between the lower PCA and the upper
interconnect cable.
42. Check operation as described in Section Four.
43. If the unit operated correctly when the spare lower interconnect cable was installed, the
original interconnect cable is bad. Install a new interconnect cable per Procedure 7.7. If the
unit does not operate properly, continue with the next step.
44. Reconnect the original lower interconnect cable to the lower PCA.
45. Reconnect the lower interconnect cable to the upper interconnect cable.